Flow format error 1C 8.3 - how to fix

Flow format error 1C 8.3 - how to fix

The message deployed in one or another failure is in many cases there are already almost half of the solution to the issue, since informs the user about the cause of the cause of the problem. However, this statement does not apply to the formulation of the "Flood Format Error" appearing in 1C versions 8.2 and 8.3. The causes of the occurrence may be the most different. Next, consider the way to eliminate the most common problems.



1
Correction of Flow Format Error in 1C 8.3 - Preview Situation

Analyzing possible causes of malfunctions, pay attention to the following points:

  1. Was it not there on the appearance of the service message about the error problems with continuous power supply?
  2. Is it not possible to update the configuration?
  3. Did the previous session be completed correctly?
  4. The problem occurs only on one device or on all computers.
  5. An error is displayed when you try to start working in the program in principle or only when reading certain data (for example, when forming a report).



2
Correction of Flow Format Error in 1C 8.3 - Deleting Service Files

The algorithm described further is very often coping with an error occurred when working in the 1C file version. In this case, there is a directory (on a PC or online), which stores the files of your 1C database (it can be arbitrary, for example, "infobase" or "1C base").

  • Go to the directory containing your information base. If you do not remember the location of the database 1c, pay attention to the path prescribed at the bottom of the program product launch window.
  • Clean this folder, leaving only files. 1cv8.cd. Work at this stage should be done very carefully in order not to overdo it with the removal.

3
Correcting errors in the stream format 1C 8.3 - clearing the cache

Such a solution to the problem is in demand in cases when on one device 1c is working correctly, and on the other - the flow error message is displayed. You can do this in several ways.

1 way

The simplest and affordable is the complete cleaning of folders "\\ 1CV8" and "\\ 1CV82".

For this you need:

  • Go to the "APPDATA" folder. She is hidden. To go to its contents, you can either make all the folders visible or immediately register the path from the disk C through the user folder to a specific device (C: \\ Users \\ 1C \\ APPDATA) and press "ENTER".
  • Find folders whose name begins with 1CV8, and manually remove them with all content.

2 way

The deletion operation described above can be carried out both in manual mode and through a batch file with the .bat extension. This utility consistently performs the processes prescribed in it.

  • Open "Notepad".
  • We prescribe a team
1
2
3
4
rD / Q / S "% UserProfile% \\ APPDATA \\ LOCAL \\ 1C \\ 1CV82 \\"
rD / Q / S "% UserProfile% \\ APPDATA \\ Roaming \\ 1C \\ 1CV82 \\"
rD / Q / S "% UserProfile% \\ APPDATA \\ LOCAL \\ 1C \\ 1CV8 \\"
rD / Q / S "% UserProfile% \\ APPDATA \\ ROAMING \\ 1C \\ 1CV8 \\"
  • Save the file by transforming it to the BAT document. To do this, go to the section of all files and save the document, assigning it .Bat extension it.
  • Get out of 1C. Double-click the saved BAT file, thus cleaning 1C 8.3 caches.

4
Correction of the Flow Format Error in 1C 8.3 - Go to Test Mode

  • Run your database configurator.
  • In the Administration section, go to testing and correction.

  • In the checks and modes section, mark "birds" all fields. Click "Run".

  • When the database testing is completed, click "close".

  • Going to the window tab, find the line of service windows, and in them - the message of the same name. Meet the results of testing and correction.

If you cannot run the configurator, you find the built-in "chdbfl.exe" file. It is loaded with the 1C base and is located in the "BIN" folder.

  • The path to the utility lies through "Program Files" and actually "1C". Before working with the utility, create a copy of your database. To do this, copy the working database directory and insert the folder window on the free domain.

  • Run the found utility.

  • Changing three points next to the free field, select the "1CV8.1CD" file in the directory.
  • Open it.

  • Mark the "bird" Correction of errors detected during testing and run the process execution.

In some cases, the elimination of the error contributed to disabling antivirus products, as well as firewalls, cleaning the registration log. You may need to delete (it is uninstalled, not a shutdown!) ESET SMART Security.



Add a comment

Your e-mail will not be published. Mandatory fields are marked *




close


загрузка